Villemagne, Victor L. and Doré, Vincent and Yates, Paul and Brown, Belinda and Mulligan, Rachel and Bourgeat, Pierrick and Veljanoski, Robyn and Rainey-Smith, Stephanie R. and Ong, Kevin and Rembach, Alan and Williams, Robert and Burnham, Samantha C. and Laws, Simon M. and Salvado, Olivier and Taddei, Kevin and Macaulay, S. Lance and Martins, Ralph N. and Ames, David and Masters, Colin L. and Rowe, Christopher C. (2014) En Attendant Centiloid. Advances in Research, 2 (12). pp. 723-729. ISSN 23480394
Villemagne2122014AIR11599.pdf - Published Version
Download (368kB)
Abstract
Aims: Test the robustness of a linear regression transformation of semiquantitative values from different Aβ tracers into a single continuous scale.
Study Design: Retrospective analysis.
Place and Duration of Study: PET imaging data acquired in Melbourne and Perth, Australia, between August 2006 and May 2014.
Methodology: Aβ imaging in 633 participants was performed with four different radiotracers: flutemetamol (n=267), florbetapir (n=195), florbetaben (n=126) and NAV4694 (n=45). SUVR were generated with the methods recommended for each tracer, and classified as high (Aβ+) or low (Aβ-) based on their respective thresholds. Linear regression transformation based on reported head-to-head comparisons of each tracer with PiB was applied to each tracer result. Each tracer native classification was compared with the classification derived from the transformed data into PiB-like SUVR units (or BeCKeT: Before the Centiloid Kernel Transformation) using 1.50 as a cut-off.
Results: Misclassification after transformation to PiB-like SUVR compared to native classification was extremely low with only 3/267 (1.1%) of flutemetamol, 1/195 (0.5%) of florbetapir, 1/45 (2.2%) of NAV4694, and 1/126 (0.8%) of florbetaben cases assigned into the wrong category. When misclassification occurred (<1% of all cases) it was restricted to an extremely narrow margin (±0.02 BeCKeT) around the 1.50 BeCKeT threshold. Conclusion: While a definitive transformation into centesimal units is being established, application of linear regression transformations provide an interim, albeit robust, way of converting results from different Aβ imaging tracers into more familiar PiB-like SUVR units.
Item Type: | Article |
---|---|
Subjects: | Journal Eprints > Multidisciplinary |
Depositing User: | Managing Editor |
Date Deposited: | 23 Jun 2023 05:18 |
Last Modified: | 16 Jan 2024 04:54 |
URI: | http://repository.journal4submission.com/id/eprint/2282 |