Simultaneous and Rapid Determination of Six Tyrosine Kinase Inhibitors in Patients with Non-Small Cell Lung Cancer Using HPLC-MS/MS

Liu, Yanping and Liu, Hua and Xia, Zhewei and Wang, Zhipeng and Yun, Yunlei and Zhang, Guanying and Huang, Lifeng and Gao, Shouhong and Chen, Wansheng and Abdel-Rehim, Mohamed (2021) Simultaneous and Rapid Determination of Six Tyrosine Kinase Inhibitors in Patients with Non-Small Cell Lung Cancer Using HPLC-MS/MS. International Journal of Analytical Chemistry, 2021. pp. 1-9. ISSN 1687-8760

[thumbnail of 5524361.pdf] Text
5524361.pdf - Published Version

Download (1MB)

Abstract

Objective. To develop a new method for quantitatively analyzing six tyrosine kinase inhibitors (gefitinib, erlotinib, icotinib, afatinib, osimertinib, and crizotinib) used in the treatment of non-small cell lung cancer (NSCLC) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methods. The analytes were detected in the selected reaction monitoring mode on a triple quadrupole mass spectrometer with the positive ionization mode. Carbamazepine was utilized as the internal standard. The pretreatment of the plasma sample was completed based on protein precipitation with acetonitrile, and the analytes were separated on an Agilent Zorbax SB-C18 reversed-phase column (2.1 mm × 100 mm, 3.5 μm, Agilent, USA) using gradient elution. The mobile phase consisted of 0.1% formic acid in water (phase A) and 0.1% formic acid in acetonitrile (phase B). The flow rate was 0.3 mL/min, and the injection volume was 5 μL. The column temperature was set and maintained at 35°C. Results. The calibration curves were linear over the range from 5.0 to 1000.0 ng/mL for gefitinib, crizotinib, and osimertinib; from 50.0 to 4000.0 ng/mL for icotinib and erlotinib; and from 5.0 to 400.0 ng/mL for afatinib. Linear correlation coefficients were >0.990 for all regression curves. The intra- and interday accuracy and precision of the method were within ±15.0% and not more than 15.0%, respectively. The mean recovery of all the analytes ranged from 70.18% to 110.76%, the matrix effect was from 88.85% to 127.58%, and stability was within ±15.0%. Conclusion. This newly developed method was sensitive, simple, and robust and could be used in therapeutic drug monitoring of six tyrosine kinase inhibitors in NSCLC patients.

Item Type: Article
Subjects: Journal Eprints > Chemical Science
Depositing User: Managing Editor
Date Deposited: 06 Feb 2023 05:32
Last Modified: 16 Apr 2024 04:19
URI: http://repository.journal4submission.com/id/eprint/302

Actions (login required)

View Item
View Item