A Minimally Invasive Technique for Short Spiral Implant Insertion with Contextual Crestal Sinus Lifting in the Atrophic Maxilla: A Preliminary Report

Corsalini, Massimo and D’Agostino, Silvia and Favia, Gianfranco and Dolci, Marco and Tempesta, Angela and Di Venere, Daniela and Limongelli, Luisa and Capodiferro, Saverio (2020) A Minimally Invasive Technique for Short Spiral Implant Insertion with Contextual Crestal Sinus Lifting in the Atrophic Maxilla: A Preliminary Report. Healthcare, 9 (1). p. 11. ISSN 2227-9032

[thumbnail of healthcare-09-00011-v3.pdf] Text
healthcare-09-00011-v3.pdf - Published Version

Download (3MB)

Abstract

The most recently reported techniques for the rehabilitation of the atrophic posterior maxilla are increasingly less invasive, as they are generally oriented to avoid sinus floor elevation with lateral access. The authors describe a mini-invasive surgical technique for short spiral implant insertion for the prosthetic rehabilitation of the atrophic posterior maxilla, which could be considered a combination of several previously described techniques based on the under-preparation of the implant site to improve fixture primary stability and crestal approach to the sinus floor elevation without heterologous bone graft. Eighty short spiral implants were inserted in the molar area of the maxilla in patients with 4.5–6 mm of alveolar bone, measured on pre-operative computed tomography. The surgical technique involved careful drilling for the preparation of implant sites at differentiated depths, allowing bone dislocation in the apical direction, traumatic crestal sinus membrane elevation, and insertion of an implant (with spiral morphology) longer than pre-operative measurements. Prostheses were all single crowns. In all cases, a spiral implant 2–4 mm longer than the residual bone was placed. Only two implants were lost due to peri-implantitis but subsequently replaced and followed-up. Bone loss values around the implants after three months (at the re-opening) ranged from 0 to 0.6 mm, (median value: 0.1 mm), while after two years, the same values ranged from 0.4 to 1.3 mm (median value: 0.7 mm). Clinical post-operative complications did not occur. After ten years, no implant has been lost. Overall, the described protocol seems to show good results in terms of predictability and patient compliance.

Item Type: Article
Subjects: Journal Eprints > Medical Science
Depositing User: Managing Editor
Date Deposited: 10 Dec 2022 12:39
Last Modified: 19 Sep 2023 07:23
URI: http://repository.journal4submission.com/id/eprint/429

Actions (login required)

View Item
View Item