Yamamoto, Yasushi and Shervani, Zameer and Shimoaki, Takatsugu and Yoshida, Daisuke and Yokoyama, Takashi and Yoshida, Tadayoshi and Taga, Keijiro and Kamaya, Hiroshi and Ueda, Issaku (2011) Study of physisorption of volatile anesthetics on phos-pholipid monolayers using a highly sensitive quartz crystal microbalance (HS-QCM). Journal of Biophysical Chemistry, 02 (02). pp. 68-74. ISSN 2153-036X

[thumbnail of JBPC20110200014_21738547.pdf] Text
JBPC20110200014_21738547.pdf - Published Version

Download (774kB)

Abstract

We have investigated the interactions between phospholipid monolayers and volatile anest-hatics. Two monolayers (dihexadecyl phosphate (DHP) and dipalmitoyl phosphatidyl choline (DPPC) and two anesthetics (halothane and enflurane) were used to observe these interac-tions using a highly sensitive quartz crystal microbalance (HS-QCM). The concentration of each anesthetic in aqueous solution was kept at 4 mM. The frequency of QCM showed no change when halothane was added to the DHP monolayer, however, it responded and de-creased when interaction occurred with DPPC monolayer. In case of enflurane addition the frequency decreased in both the monolayers of DHP and DPPC. The frequency change followed the following order of monolayer-anesthetic interactions: DHP-halothane.